Human T-Cell, Immune Regulator 1 (TCIRG1) ELISA Kit, 96 well plate

Human T-Cell, Immune Regulator 1 (TCIRG1) ELISA Kit, 96 well plate

Size

5x96T

Catalog no.

EKU07582

Price

3918 EUR

Buy
NameValue
Tissue cell
Verified applications ELISA
Assay duration 3 hours
Shipping requirements Blue ice
Assay class Sandwich
Use for 8 months
Sensitivity limit 6,0 pg/mL
ELISA detection Colorimetric
Detection limits 15.62-1000 pg/mL
Estimated production time 7-11 business days
Research main area Infection immunity;
Verified reactivity Homo sapiens (Human)
Gene number Please refer to GenBank
Protein number Please refer to Uniprot
Alternate protein number Please refer to SwissProt
Gene name T-Cell, Immune Regulator 1
Samples to be analyzed Serum and other biological fluids.
Protocol Please see ELISA's datasheet, otherwise contact us
Notes For research use only. Not for diagnostic procedures.
Test ELISA Enzyme-linked immunosorbent assays Code 90320007 SNOMED
QC The Kit is manufactured at ISO 9001 and ISO 13485 certified facilities.
ELISA's cross-reactivity This assay doesn't seem to cross-react with other species. For more information about cross-reactivity please contact us.
Alternate gene name Stv1; Vph1; ATP6N1C; ATP6V0A3; Atp6i; OC-116kDa; OC116; OPTB1; TIRC7; a3; V-Type Proton ATPase 116 kDa Subunit A Isoform 3; Osteoclastic proton pump 116 kDa subunit
Storage recommendation -20°C. Bring all reagents to room temperature before beginning test. The kit may be stored at 4°C for immediate use within two days upon arrival. Reseal any unused strips with desiccant pack. Minimize freeze/thaw cycles.
Warnings The Stop Solution is acidic. Do not allow to contact skin or eyes. Calibrators, controls and specimen samples should be assayed in duplicate. Once the procedure has been started, all steps should be completed without interruption.
ELISA's specificity This assay has high sensitivity and excellent specificity for detection of T-Cell, Immune Regulator 1 (TCIRG1). No significant cross-reactivity or interference between T-Cell, Immune Regulator 1 (TCIRG1) and analogues was observed.
Precision of the test Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level T-Cell, Immune Regulator 1 (TCIRG1) were tested 20 times on one plate, respectively. Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level T-Cell, Immune Regulator 1 (TCIRG1) were tested on 3 different plates, 8 replicates in each plate. CV(%) = SD/meanX100 Intra-Assay: CV
ELISA's stability The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition. To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Properties E05 478 566 350 170 or Enzyme-Linked Immunosorbent Assays,E05 478 566 350 170 or Enzyme-Linked Immunosorbent Assays,Human proteins, cDNA and human recombinants are used in human reactive ELISA kits and to produce anti-human mono and polyclonal antibodies. Modern humans (Homo sapiens, primarily ssp. Homo sapiens sapiens). Depending on the epitopes used human ELISA kits can be cross reactive to many other species. Mainly analyzed are human serum, plasma, urine, saliva, human cell culture supernatants and biological samples.
Description For cells, cell lines and tissues in culture till half confluency.Complexes, systems, regulators, immune RNAs and non immune controls that can react with a specific antigen epitope.A microtiter plate (spelled Microtiter is a registered trade name in the United States) or microplate or micro well plate or multiwell, is a flat plate with multiple "wells" used as small test tubes. The microplate has become a standard tool in analytical research and clinical diagnostic testing laboratories. A very common usage is in the enzyme-linked immunosorbent assay (ELISA), the basis of most modern medical diagnostic testing in humans and animals. A microplate typically has 6, 24, 96, 384 or 1536 sample wells arranged in a 23 rectangular matrix. Some microplates have even been manufactured with 3456 or 9600 wells, and an "array tape" product has been developed that provides a continuous strip of microplates embossed on a flexible plastic tape.
Assay principle The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to T-Cell, Immune Regulator 1 (TCIRG1). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to T-Cell, Immune Regulator 1 (TCIRG1). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain T-Cell, Immune Regulator 1 (TCIRG1), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of T-Cell, Immune Regulator 1 (TCIRG1) in the samples is then determined by comparing the O.D. of the samples to the standard curve.